Construction Technology
The methods, materials and systems behind every AWICON build — explained so clients understand the craft, not only the finish.
Brickwork, steel, glass, paint, concrete and roofing — each explained below with the methods we use on site.






Whether we are building your family home or a larger institutional project, the same trades apply. Great homes are not accidents — they come from sequenced work, correct specifications and site discipline. Below is how AWICON approaches the technologies behind a durable house in Kenya’s climate.
Brickwork & Blockwork Technology
Walls carry load, resist weather and define space. We specify bricks or concrete blocks by compressive strength, dimensional tolerance and water absorption — critical in both highland and coastal Kenya.
Bond patterns (English, Flemish, stretcher) are chosen for structural behaviour and appearance. Mortar mixes are controlled (typically 1:4 or 1:6 cement:sand) with clean water and proper curing so joints do not become the weak link.
- Damp-proof courses at ground level to stop rising moisture
- Movement joints in long walls to control cracking
- Reinforced blockwork where required for seismic and wind loads
- Facing brick selection for weather-exposed elevations
Concrete & Formwork
Concrete is the backbone of most modern builds in Kenya. Strength grades (e.g. C20, C25, C30) are matched to the element: foundations, columns, slabs, beams. We insist on plant-batched mix where volumes allow, with slump tests and cube samples for verification.
Formwork must be rigid, sealed and correctly propped. Poor formwork shows forever in the finished face. Cover to reinforcement is protected so steel does not corrode inside the concrete.
- Designed mix ratios and water–cement control
- Vibration to remove air voids without segregation
- Curing (wet hessian, curing compounds) for strength gain
- Construction joints planned, never accidental
Steel & Reinforcement Technology
Reinforcement (rebar) turns concrete into a composite that resists both compression and tension. Bar diameters, spacing and lap lengths follow structural drawings. We check mill certificates and keep bars clean of mud and oil before casting.
Structural steel frames — beams, columns, trusses — are fabricated to tolerance, with correct welding procedures and bolt grades. Fire protection and corrosion coatings are specified for the exposure condition.
- High-yield deformed bars (Y12, Y16, Y20, Y25) as designed
- Chair and spacer systems for correct cover
- Shop drawings and fabrication QA for steel frames
- Protective coatings for coastal and industrial sites
Aluminium & Facade Systems
Aluminium is light, corrosion-resistant and precise. Casement, sliding and curtain-wall systems are selected for wind load, water tightness and thermal performance. Profiles may be thermally broken for comfort in hot or cool climates.
Installation quality decides whether a window lasts ten years or thirty. We measure openings carefully, use correct anchors, sealants and drainage paths so water is managed, not trapped.
- Powder-coated or anodised finishes for UV and salt air
- Multi-point locking and quality hardware
- Structural silicone and gasket systems where specified
- Compatibility with glass type and thickness
Glass Technology
Glass is a structural and environmental product, not only a view. Toughened, laminated and insulated glass units (IGUs) are chosen for safety, security, solar control and acoustic performance.
In Kenya’s strong sun, solar-control and low-E coatings reduce heat gain and glare. Edge clearances, setting blocks and sealants are critical — most glass failures start at the edge, not the centre of the pane.
- Safety glass where required by code (doors, low levels, balustrades)
- Laminated glass for security and residual integrity after breakage
- Correct bite and support in aluminium or steel frames
- Cleaning and protection during construction
Paint & Surface Technology
Paint is the first line of defence against weather and the last layer of visual quality. Substrate preparation matters more than the top coat: dust, laitance, moisture and oil must be removed. Primers are matched to substrate (masonry, metal, timber).
We use systems — primer + undercoat + finish — not single coats of “whatever is cheapest.” Exterior emulsions and textured coatings are selected for UV stability and rain resistance in Kenyan conditions.
- Moisture testing before painting
- Crack filling and joint treatment
- Low-VOC options for interiors and healthcare
- Scheduled recoating for exposed steel and timber
Roofing Technology
The roof fails, the building fails. We detail slopes, overlaps, flashings and gutters so water has a clear path off the structure. Sheet materials (IT4, IBR, standing seam) and tile systems each have fixing patterns and underlay requirements.
Insulation and vapour control layers are included where energy performance or condensation control is required. Coastal projects get enhanced corrosion protection on metal components.
- Correct purlin spacing and fixing density for wind zones
- Ridge, valley and abutment flashings detailed in drawings
- Rainwater goods sized for design storms
- Access and fall-arrest provision for maintenance
Scaffolding & Access Technology
Safe access is not optional. Modular scaffolding is designed for load, height and duration of use. Sole boards, base jacks, ledgers, transoms and guardrails form a system — missing one element compromises the rest.
Inspections, tagging and competent persons are part of daily site discipline. Working at height without harnesses or edge protection is not tolerated on AWICON sites.
- Designed scaffold layouts for multi-storey and facade work
- Weekly formal inspections and after weather events
- Integration with debris netting and public protection
- PPE culture: helmets, boots, harnesses, high-vis
MEP — Electrical, Plumbing & Mechanical
Buildings work when services work. Electrical designs cover load, earthing, distribution boards and lighting. Plumbing covers water supply, drainage, hot water and, where specified, solar thermal. Coordination drawings stop clashes between ducts, pipes and structure.
First fix (concealed) and second fix (visible) stages are planned so finishes are not destroyed by late service changes. Testing and commissioning are documented before handover.
- Kenya Power and local authority compliance
- Concealed conduit and trunking routes planned early
- Pressure testing of water and drainage systems
- As-built drawings for future maintenance
Technology with accountability
Specifications mean nothing without site discipline. That is the AWICON difference.